Incident ID |
TX06922-2758 |
Dam Name |
RANNEFELD DAM |
Downstream Hazard Potential |
S |
State |
TX |
Incident Date |
10/17/1994 |
Incident Type |
Non-failure |
Incident Driver |
Seepage/internal Erosion |
Incident Mechanism 1 |
Piping |
Incident Mechanism 2 |
|
Incident Mechanism 3 |
|
Incident Description |
PIPING AT S.S. |
Named Hydrologic Event |
|
EAP Enacted (Y/N) due to Incident |
|
Fatalities (Number) |
|
Number of People Evacuated |
|
Number of Habitable Structures Evacuated |
|
Number of Habitable Structures Flooded |
|
Other Infrastructure Impacts |
|
Economic Damages (in $) |
|
Volume released at failure (ac-ft) |
|
Response |
|
Additional Remarks or Updates |
|
Incident Time |
|
Incident Duration |
|
Incident Report Produced |
|
Information Sources |
TX DEQ |
Owner Type |
P |
Dam Type |
RE |
Primary Purpose(s) |
|
EAP |
Y |
Year Completed |
1994 |
Year Modified |
1995 |
Dam Height |
16 ft |
Max Storage (ac-ft) |
115 ac-ft |
Surface Area (acres) |
7 acres |
River Name |
TR-DECKER BRANCH |
Latitude |
30.1497 |
Longitude |
-95.6966 |
Regulatory Agency(ies) |
TCEQ |
NID Number |
TX06922 |
Attachments |
|