Incident ID |
CO00762-3171 |
Dam Name |
ALBERTA PARK |
Downstream Hazard Potential |
H |
State |
CO |
Incident Date |
07/18/2017 |
Incident Type |
Non-failure |
Incident Driver |
Manmade Action |
Incident Mechanism 1 |
Other |
Incident Mechanism 2 |
|
Incident Mechanism 3 |
|
Incident Description |
While drilling in the embankment with hollow stem augers an apparent connection was made with a pervious seam and elevated pressures associated with the drilling process caused a surge of muddy seepage and an increase in volume of seepage from a know exit point. |
Named Hydrologic Event |
|
EAP Enacted (Y/N) due to Incident |
Yes |
Fatalities (Number) |
|
Number of People Evacuated |
|
Number of Habitable Structures Evacuated |
|
Number of Habitable Structures Flooded |
|
Other Infrastructure Impacts |
|
Economic Damages (in $) |
|
Volume released at failure (ac-ft) |
|
Response |
Drill was stopped, the hole was grouted and the situation returned to "normal". Reservoir was lowered and an emergency seepage collection system and stability butress were constructed. |
Additional Remarks or Updates |
developed a plan to install a filter and butress |
Incident Time |
|
Incident Duration |
2 days |
Incident Report Produced |
Yes |
Information Sources |
CO DWR |
Owner Type |
S |
Dam Type |
RE |
Primary Purpose(s) |
FR |
EAP |
Y |
Year Completed |
1953 |
Year Modified |
0 |
Dam Height |
32 ft |
Max Storage (ac-ft) |
812 ac-ft |
Surface Area (acres) |
39 acres |
River Name |
PASS CREEK-TR |
Latitude |
37.4703 |
Longitude |
-106.766 |
Regulatory Agency(ies) |
DWR |
NID Number |
CO00762 |
Attachments |
|