Incident ID |
MD00531-3088 |
Dam Name |
MARTIN FARM POND DAM |
Downstream Hazard Potential |
|
State |
MD |
Incident Date |
05/05/2016 |
Incident Type |
Failure |
Incident Driver |
Deterioration Or Poor Condition |
Incident Mechanism 1 |
Spillway Pipe Failure |
Incident Mechanism 2 |
Accident Or Misoperation |
Incident Mechanism 3 |
|
Incident Description |
CMP riser plugged with debris triggered flow in emergency. CMP spillway barrel was partially collapsed and deteriorated, downstream embankment eroded away around spillway. Owner removed riser, creating a partial uncontrolled release. |
Named Hydrologic Event |
|
EAP Enacted (Y/N) due to Incident |
No |
Fatalities (Number) |
|
Number of People Evacuated |
|
Number of Habitable Structures Evacuated |
|
Number of Habitable Structures Flooded |
|
Other Infrastructure Impacts |
|
Economic Damages (in $) |
|
Volume released at failure (ac-ft) |
|
Response |
|
Additional Remarks or Updates |
Owner made excavation in embankment and removed riser, creating a partial uncontrolled release. |
Incident Time |
|
Incident Duration |
|
Incident Report Produced |
|
Information Sources |
MDE Dam Safety Program |
Owner Type |
|
Dam Type |
RE |
Primary Purpose(s) |
|
EAP |
|
Year Completed |
0 |
Year Modified |
0 |
Dam Height |
21 ft |
Max Storage (ac-ft) |
25 ac-ft |
Surface Area (acres) |
0 acres |
River Name |
|
Latitude |
39.5237 |
Longitude |
-76.4438 |
Regulatory Agency(ies) |
MD DAM SAFETY |
NID Number |
MD00531 |
Attachments |
|