HEATER RESERVOIR #2 - OR00729-3162


Incident ID OR00729-3162
Dam Name HEATER RESERVOIR #2
Downstream Hazard Potential S
State OR
Incident Date 11/23/2016
Incident Type Failure
Incident Driver Other
Incident Mechanism 1 Spillway Pipe Failure
Incident Mechanism 2 Sliding
Incident Mechanism 3
Incident Description Deformation of a very thin steel conduit that was very poorly encased in concrete. caused the outlet and part of the pipe and the lower 2/3 of the downstream face to move about ten feet as a slide, partly rotational, partly translational.
Named Hydrologic Event
EAP Enacted (Y/N) due to Incident No
Fatalities (Number) 0
Number of People Evacuated 20
Number of Habitable Structures Evacuated 0
Number of Habitable Structures Flooded 0
Other Infrastructure Impacts Roads
Economic Damages (in $) $1 to $100,000
Volume released at failure (ac-ft)
Response
Additional Remarks or Updates The reservoir drained fairly slowly from the detached pipe up through the slide scarp, and it flooded a Christmas tree packing and shipping area below the dam, which was occupied with about 20 workers when the flooding started. No injuries, but loss of productivity and some pumping required, and flooding sufficient to close but not damage a County road. Probably cost of 10K in damage, but with 200 K or more if the dam was to repaired to full storage. Owner plans to reconstruct as a non-statutory dam
Incident Time
Incident Duration
Incident Report Produced
Information Sources OR Dam Safety
Owner Type P
Dam Type RE
Primary Purpose(s) I
EAP NR
Year Completed 1981
Year Modified 0
Dam Height 28 ft
Max Storage (ac-ft) 42 ac-ft
Surface Area (acres) 4 acres
River Name CENTER FORK DRIFT CREEK
Latitude 44.884
Longitude -122.709
Regulatory Agency(ies) OWRD
NID Number OR00729