EDNA YON DAM - SC00364-3127


Incident ID SC00364-3127
Dam Name EDNA YON DAM
Downstream Hazard Potential H
State SC
Incident Date 09/12/2017
Incident Type Non-failure
Incident Driver Hydrologic/flooding
Incident Mechanism 1 Insufficient Spillway Capacity
Incident Mechanism 2 Accident Or Misoperation
Incident Mechanism 3 Other
Incident Description Owners had filled in primary spillway due to leakage at some point historically so that auxiliary spillway is only avenue for flow.  Then owners constructed a road across auxiliary spillway with undersized culvert pipes.  Permits/approval from the State were not obtained for any of this work.  During Hurricane Irma, the road bed washed out causing a sudden, uncontrolled release.
Named Hydrologic Event Hurricane Irma
EAP Enacted (Y/N) due to Incident No
Fatalities (Number) 0
Number of People Evacuated 0
Number of Habitable Structures Evacuated 0
Number of Habitable Structures Flooded 0
Other Infrastructure Impacts
Economic Damages (in $)
Volume released at failure (ac-ft)
Response The State issued an Emergency Order to require the dam owner immediately lower water level under direction of a licensed Professional Engineer, submit a detailed investigation by a licensed Professional Engineer, and submit a Plan of Action for the repair
Additional Remarks or Updates
Incident Time
Incident Duration
Incident Report Produced
Information Sources SC Dam Safety
Owner Type P
Dam Type RE
Primary Purpose(s) R
EAP N
Year Completed 1962
Year Modified 0
Dam Height 17 ft
Max Storage (ac-ft) 316 ac-ft
Surface Area (acres) 40 acres
River Name HOLLOW CREEK
Latitude 33.6301
Longitude -81.2444
Regulatory Agency(ies) SC DHEC
NID Number SC00364