DAVIDS MILLPOND DAM - SC00638-3120


Incident ID SC00638-3120
Dam Name DAVIDS MILLPOND DAM
Downstream Hazard Potential S
State SC
Incident Date 09/16/2018
Incident Type Failure
Incident Driver Hydrologic/flooding
Incident Mechanism 1 Insufficient Spillway Capacity
Incident Mechanism 2 Overtopping
Incident Mechanism 3 Erosion
Incident Description Simply appears dam overtopped during the heavy rainfall associated with Hurricane Florence and suffered headcut erosion on the downstream slope at location of primary spillway.  Auxiliary spillway is a concrete chute but is severely restricted by "orifice" at outlet.
Named Hydrologic Event Hurricane Florence
EAP Enacted (Y/N) due to Incident No
Fatalities (Number) 0
Number of People Evacuated 0
Number of Habitable Structures Evacuated 0
Number of Habitable Structures Flooded 0
Other Infrastructure Impacts Roads
Economic Damages (in $)
Volume released at failure (ac-ft)
Response State Dam Safety Program performed a full inspection following the breach of this dam. The inspection report will contain a requirement that the Owner hire an engineer and submit either a permit application for repair or removal of the dam.
Additional Remarks or Updates Report on dam failures associated with Hurricane Florence to be released by Geotechnical Extreme Event Reconnaisance (GEER) group at some point in the future. GEER team field work occurred during month of September 2018.
Incident Time
Incident Duration
Incident Report Produced
Information Sources SC Dam Safety
Owner Type P
Dam Type RE
Primary Purpose(s) O
EAP Y
Year Completed 1870
Year Modified 0
Dam Height 9 ft
Max Storage (ac-ft) 394 ac-ft
Surface Area (acres) 45 acres
River Name NAKED CREEK
Latitude 34.6443
Longitude -79.7482
Regulatory Agency(ies) SC DHEC
NID Number SC00638