MOON LAKE DAM - SC01800-3131


Incident ID SC01800-3131
Dam Name MOON LAKE DAM
Downstream Hazard Potential H
State SC
Incident Date 06/01/2018
Incident Type Non-failure
Incident Driver Deterioration Or Poor Condition
Incident Mechanism 1 Spillway Erosion/head Cutting
Incident Mechanism 2
Incident Mechanism 3
Incident Description A late spring storm apparently caused severe head cut erosion at the downstream end of the auxiliary spillway.  Spillway erosion occurred sometime in the Spring of 2018 - exact date is unknown.  County imagery shows the headcuting just starting around 3/8/2018 and Google Earth imagery shows highly progressed headcutting by 6/3/2018.   The Department became aware of headcutting in late June 2018 when very little dam crest remained to prevent a breach.
Named Hydrologic Event N/A
EAP Enacted (Y/N) due to Incident No
Fatalities (Number) 0
Number of People Evacuated 0
Number of Habitable Structures Evacuated 0
Number of Habitable Structures Flooded 0
Other Infrastructure Impacts
Economic Damages (in $)
Volume released at failure (ac-ft)
Response The State issued an Emergency Order to require the dam owner immediately lower water level under direction of a licensed Professional Engineer, submit a detailed investigation by a licensed Professional Engineer, and submit a Plan of Action for the repair
Additional Remarks or Updates
Incident Time
Incident Duration
Incident Report Produced
Information Sources SC Dam Safety
Owner Type P
Dam Type RE
Primary Purpose(s) PR
EAP Y
Year Completed 1969
Year Modified 0
Dam Height 22 ft
Max Storage (ac-ft) 74 ac-ft
Surface Area (acres) 7 acres
River Name TR-SOUTH TYGER RIVER
Latitude 34.9828
Longitude -82.2257
Regulatory Agency(ies) SC DHEC
NID Number SC01800