BAXLEY 501 POND DAM - SC01805-3122


Incident ID SC01805-3122
Dam Name BAXLEY 501 POND DAM
Downstream Hazard Potential S
State SC
Incident Date 09/16/2018
Incident Type Failure
Incident Driver Hydrologic/flooding
Incident Mechanism 1 Overtopping
Incident Mechanism 2 Erosion
Incident Mechanism 3
Incident Description Hurricane Florence dropped heavy precipation on the watershed over approximately 72 hours, causing the dam to overtop.  Dam was previously heavily impacted from Hurricane Matthew in 2016.  Failure location is also where a void from an overturned tree was located, which is suspected as cause of the breach occurring where it did.
Named Hydrologic Event Hurricane Florence
EAP Enacted (Y/N) due to Incident No
Fatalities (Number) 0
Number of People Evacuated 0
Number of Habitable Structures Evacuated 0
Number of Habitable Structures Flooded 0
Other Infrastructure Impacts
Economic Damages (in $)
Volume released at failure (ac-ft)
Response State Dam Safety Program performed a full inspection following the breach of this dam. The inspection report will contain a requirement that the Owner hire an engineer and submit either a permit application for repair or removal of the dam.
Additional Remarks or Updates Report on dam failures associated with Hurricane Florence to be released by Geotechnical Extreme Event Reconnaisance (GEER) group at some point in the future. GEER team field work occurred during month of September 2018.
Incident Time
Incident Duration
Incident Report Produced
Information Sources SC Dam Safety
Owner Type P
Dam Type RE
Primary Purpose(s) R
EAP Y
Year Completed 1953
Year Modified 0
Dam Height 7 ft
Max Storage (ac-ft) 141 ac-ft
Surface Area (acres) 22 acres
River Name LITTLE REEDY CREEK
Latitude 34.1114
Longitude -79.3352
Regulatory Agency(ies) SC DHEC
NID Number SC01805
Attachments