ELKINS LAKE DAM - TX02956-3597


Incident ID TX02956-3597
Dam Name ELKINS LAKE DAM
Downstream Hazard Potential H
State TX
Incident Date 05/18/2024
Incident Type Non-failure
Incident Driver Hydrologic/flooding
Incident Mechanism 1 Spillway Chute Failure
Incident Mechanism 2
Incident Mechanism 3
Incident Description Spillway chute collapsed
Named Hydrologic Event Texas Severe Storms, Straight-line Winds, Tornadoes, and Flooding (DR-4781-TX)
EAP Enacted (Y/N) due to Incident Unknown
Fatalities (Number)
Number of People Evacuated 0
Number of Habitable Structures Evacuated 0
Number of Habitable Structures Flooded 0
Other Infrastructure Impacts None
Economic Damages (in $) Unknown
Volume released at failure (ac-ft)
Response Owner constructed an emergency cofferdam to prevent further loss of water
Additional Remarks or Updates TCEQ performed a routine inspection and upon arrival was notified that the spillway chute had collapsed over the weekend. The area had received 16-20 inches of rain over the previous two months. TCEQ recommended they consult with engineer for repairs
Incident Time
Incident Duration
Incident Report Produced Yes
Information Sources TCEQ
Owner Type P
Dam Type RE
Primary Purpose(s) IR
EAP Y
Year Completed 1920
Year Modified 2002
Dam Height 31 ft
Max Storage (ac-ft) 1766 ac-ft
Surface Area (acres) 85 acres
River Name PRAIRIE BRANCH
Latitude 30.6569
Longitude -95.532
Regulatory Agency(ies) TCEQ
NID Number TX02956
Attachments