PRUITTS DAM - VA075007-3541


Incident ID VA075007-3541
Dam Name PRUITTS DAM
Downstream Hazard Potential U
State VA
Incident Date 07/22/2022
Incident Type Failure
Incident Driver Deterioration Or Poor Condition
Incident Mechanism 1 Spillway Riser Failure
Incident Mechanism 2 Spillway Pipe Failure
Incident Mechanism 3
Incident Description Pipe Collapse: Owner siphoned water level down to discover erosion in vicinity of riser. Probable failure of riser, riser elbow or outlet pipe. Corrogated metal pipe riser developed signficant holes that drained the pond. Date of failure is estimated to be late spring of 2022. No known risks to embankment that may cause breach failure of dam.
Named Hydrologic Event
EAP Enacted (Y/N) due to Incident No
Fatalities (Number) 0
Number of People Evacuated 0
Number of Habitable Structures Evacuated 0
Number of Habitable Structures Flooded 0
Other Infrastructure Impacts
Economic Damages (in $)
Volume released at failure (ac-ft)
Response
Additional Remarks or Updates
Incident Time
Incident Duration
Incident Report Produced Unknown
Information Sources VA Dam Safety
Owner Type P
Dam Type RE
Primary Purpose(s) R
EAP Y
Year Completed 1968
Year Modified 0
Dam Height 25 ft
Max Storage (ac-ft) 180 ac-ft
Surface Area (acres) 15 acres
River Name TR-BIG LICKING HOLE CREEK
Latitude 37.7873
Longitude -77.9736
Regulatory Agency(ies) DEPARTMENT OF CONSERVATION AND RECREATION
NID Number VA075007
Attachments